FOR CATEGORY 2, 3 & 4 INSTALLATIONS

DN25 Residential Valve Set Manifold Riser

RMR25

RMR25 1”/DN25 Fire Sprinkler Residential Valve Set Manifold Riser complete with SIKA® VKF flow switch alarm for Category 2, 3 & 4 Residential Fire Sprinkler systems.

The SIKA VKF Fire Sprinkler flow switch manufactured by SIKA is approved with LPCB, CE, UKCA to EN 12259-5 making it suitable for BS9251:2021 from BSI and also European EN16925:2018 installations.

DN25 Residential Valve Set Manifold Riser USP’s include:

  • One piece forging to reduce leak paths
  • Forged mounting positions for Valve Monitor giving robust installations
  • No-Loss valve for pressure gauge removal in the field
  • ½” BSP female port for further accessories like Pressure Switch or Test Solenoid Valve
  • O-ring grove for flow switch to enhance leak protection
  • 25mm Full bore valves for high flow rates
  • Ultra low pressure drop design unique to DN25 Fire Sprinkler Residential Valve Set
  • LPCB certified VKF SIKA flow switch
  • CE, UKCA and WRAS SIKA flow switch

The Patent pending RiserTeQ™ RMR25 DN25 Fire Sprinkler Residential Valve Set is focused on saving space within a Residential environment for DN25 Fire Sprinkler Residential Valve Set applications. It can come complete with a Dual Sensor Valve Monitor to monitor the position of the inlet ball valve for tamper monitoring.

The RMR25 DN25 Fire Sprinkler Residential Valve Set features an O-ring grove for the SIKA Fire Sprinkler flow switch which helps to make it robust and reliable across the full product lifetime and all pressure ranges.


Fire Sprinkler Residential Valve Set DN25 Manifold Riser O-Ring sealing method for Fire Sprinkler Flow Switch

RMR25 DN25 Fire Sprinkler Residential Valve Set technical data

Manifold

SizeDN25
Inlet connectionFemale G1”
Outlet connectionFemale G1”
Test point connectionFemale G1”
MediumWater
Medium temperature5 – 50 °C
Ambient temperature5 – 60 °C
Maximum pressure rating12 bar
Inlet valve internal boreDN25
Test point valve internal boreDN25

Valve Monitor

Cable entries2 x M20 Cable Glands – IP66
2 x Rubber Glands – IP66
EOL Resister InputYes
Flow Switch / Alarm Resister InputYes
Connector Type for ResistersRemovable 2 Pin
Ingress ProtectionIP54
Maximum Voltage24 VDC

Pressure gauge

Size50mm
Pressure range0 – 16 bar
Accuracy1.6 FSD
StandardEN 837-1
Pressure scale0.5 bar
Pressure connectionG1/4″
Medium temperature5 – 50 °C

No-loss connector

Max pressure16 bar
Ambient temperatures5 – 50 °C
Process connectionsG1/4″ x 1/4″ BSPT
Pressure loss data – RMR DN25 Fire Sprinkler Residential Valve Set

DN25

Dimensions

Dimensions of RMR Fire Sprinkler Residential Valve Set Riser Manifold

RMR25

L1L2L3L4L5L6
344.5162178.5270143.5112
D1D2D3D4D5D6F1
1″ BSPP ISO 2281″ BSPP ISO 228G3/4″ ISO 2281″ BSPP ISO 228G1/2″G1/4″ø6

Find Residential Riser Manifold materials of construction and all product data in the datasheet. Find the download below.

VKF Fire Sprinkler Flow Switch

ModelVKF25 M2 Brass
For RiserTeQ valve set sizeDN25
Max pressure rating12 Bar
Medium temperature-25 – 100 °C
Ambient temperature-25 – 70 °C
Setpoint (sensitivity)25 L/min*
Maximum surge5.5 m/s
MediumWater
* Water @ 20°C, Vertical Pipe (Flow Direction Upwards). Tolerance +/- 15%. Must be installed according to the manual.

Electrical specification

Electrical connectionPlug connector DN EN 175301-803-A inc. cable socket
Switch type1 x SPST
Electrical ratingMax. 26 VA, 20W
Switching voltageMax. 230 VAC, 48 VDC
Maximum rated current @ 230 VAC0.1 A
Maximum rated current @ 24 VAC0.8 A
Minimum rated current1 mA
Ingress protectionIP65
Protection class (EN 60730-1)Class II

Materials of construction

Body / HolderPPE+PS Noryl™ 30% GF
Paddle System / Disk / RivetBrass (CW614N, CW508L)
AxisStainless Steel 1.4571
MagentHard Ferrite

VKF Fire Sprinkler Flow switch approvals